Q1: What is a synchronous flow divider?
A: A synchronous flow divider-also known as a flow-dividing motor-is a positive-displacement flow-distribution component. It features a rigid, coaxial, multi-section gear assembly. As the unit rotates, each section delivers a fixed displacement, splitting a single hydraulic oil input into multiple output streams at a precise, constant ratio. By supplying oil to various hydraulic cylinders or motors, it ensures that multiple actuators extend and retract in perfect synchronization. As the core component in mechanical synchronization systems, it relies on its mechanical structure-rather than electrical signals-to distribute flow. It is widely used in applications such as multi-cylinder lifting, platform leveling, multi-point synchronous clamping, and synchronous drive operations.
Note: Synchronous flow dividers achieve speed synchronization; they cannot automatically eliminate cumulative positional errors that may arise over long strokes. High-precision position synchronization requires an additional position-correction mechanism.
Q2: Which is better: a synchronous flow divider or an electronically controlled synchronization system? How should I choose?
A: Neither is inherently superior; the choice depends on your specific operational requirements:
✅ Electronically controlled synchronization (sensors + PLC + servo/proportional valves): Offers higher theoretical synchronization precision and allows for real-time deviation compensation. However, the system is costly and places high demands on oil cleanliness, power supply, and signal wiring. It is also susceptible to failures caused by oil contamination, electromagnetic interference, or wiring degradation, and requires specialized maintenance.
✅ Synchronous flow divider: Utilizes a rigid mechanical linkage. The circuit design is simple, free from complex electrical signals, and highly resistant to oil contamination and electromagnetic interference. It is well-suited for harsh operating environments, offers a lower initial investment, and is both stable and durable.
👉 Selection advice: Choose a synchronous flow divider if you are working in a harsh environment, have a limited budget, do not require ultra-high precision, or prefer a low-maintenance solution. Opt for an electronically controlled system only if you require extremely high synchronization precision, can accommodate complex electrical controls, and have access to professional maintenance and operational support.
Q3: What is the typical synchronization precision, and what factors affect it? A: For gear-type synchronous flow dividers, the synchronization accuracy is typically between ±1.5% and ±2.5% under standard test conditions-specifically, when loads across the various branches are similar and the operating speed falls within the rated range. This accuracy is not a fixed value; it can be compromised by factors such as significant load imbalances, operating speeds outside the recommended range, hydraulic fluid contamination, or fluctuations in oil temperature. Furthermore, as the components experience long-term wear, internal leakage increases, leading to a gradual decline in accuracy.
Q4: Can synchronous flow dividers provide synchronization in both directions? What should be considered during the return stroke?
A: Yes. Bidirectional synchronous flow dividers function as flow dividers during the extension stroke and as flow combiners during the return stroke, ensuring equal flow distribution in both directions. This type is the most common choice for lifting platforms.
⚠️ Important Note: A synchronous flow divider only ensures equal flow distribution; it cannot prevent an "over-speed" descent caused by a load's own weight (gravity). When a load is present during the return stroke, a counterbalance valve (or load-holding valve) must be used to lock the load and control its descent speed. A simple one-way flow control valve (throttle valve) is only suitable for regulating return-flow speed under light loads and cannot serve as a substitute for a counterbalance valve in vertical lifting applications. Unidirectional (one-way) synchronous flow dividers only provide flow division (synchronization) during the extension stroke and lack flow-combining (synchronization) capabilities during the return stroke. Please ensure you clearly distinguish between unidirectional and bidirectional models when selecting your equipment.